November 18, 2026 · Paediatric anaesthesia · DOI: 10.1002/pan.70352

Effect of Wrist Extension Angle on Radial and Ulnar Artery Sonoanatomy in Children: A Prospective Ultrasound Study.

Listen to this summary

This study examined how wrist extension angle (0°, 30°, 45°) and child age and weight affect the sonoanatomy of the radial and ulnar arteries in 180 anesthetized children aged 0-120 months, to identify the most favorable profile for ultrasound-guided cannulation. Wrist extension at 30° minimized skin-to-artery distance for both vessels, and the ulnar artery was widest at this angle, while the radial artery was widest at 0°. The authors conclude that 30° provides the most favorable profile overall, but because cannulation success was not measured, they recommend individualized ultrasound assessment rather than a fixed wrist position.

Sehriban Zeynep Altinbas, Fatma Nur Duruk Erkent, Volkan Baytas, Tugce Ata, Aysegul Guven, Ozlem Selvi Can